Total Heat Recovery Fresh Air Ventilators

A fresh air ventilator brings filtered outdoor air into a building and removes the equivalent volume of stale indoor air, while the heat exchanger in the middle recovers what the outgoing air contained. ROTER's fresh air series covers the full range of forms a project asks for: packaged ventilators for public buildings, wall-mounted and cabinet-type units for homes and small commercial spaces, and specialised haze removal units for environments where fine particulate control is the priority.

Standard and haze removal total heat recovery ventilators

The standard and haze removal total heat recovery fresh air ventilator combines a total heat recovery core with multi-layer filtration, smart mode real-time monitoring and intelligent control, and a full-circle airflow path for high effective flow at low noise. Haze removal versions are specified where PM2.5 removal is the main driver.

DC inverter total heat recovery ventilator

The DC inverter total heat recovery ventilator adds inverter-driven fan control to the same recovery core, so the unit matches airflow to real demand rather than running at full output continuously. That suits buildings with widely varying occupancy.

Single flow positive pressure haze removal ventilator

The single flow positive pressure fresh air ventilator uses primary plus high-efficiency dual-layer filtration with a 99.9% PM2.5 removal rate, an HD LCD control panel and a compact body that is quick to install. Because the unit holds positive pressure against the space, unfiltered air does not leak back in around doors.

Smart fresh air systems for residential and small commercial spaces

Total heat recovery units for larger volumes

Unit Airflow Typical use
Medium ceiling-mounted heat recovery unit 1,500–15,000 m³/h KTVs, hotels, malls, factories, offices, restaurants, banks, schools, kindergartens, hospital wards
Medium ceiling-mounted total heat recovery unit 1,000–15,000 m³/h Hotels, guest rooms, small meeting rooms and homes, installed in the ceiling to leave the floor clear
Vertical total heat recovery unit Floor standing Underground garages, large supermarkets, swimming pools, malls, offices and restaurants, placed in an equipment room

Sizing fresh air volume

Fresh air volume should be taken as the larger of the per-person minimum and the air-change based requirement. Reference figures from the ROTER manual are 30 m³/h per person for a general office, 30–50 m³/h per person for a high-grade office or residence, and 15–25 m³/h per person for a shopping mall; on air change, general rooms need 1–2 ACH, computer rooms 2–4 ACH and smoking-intensive meeting rooms 3–8 ACH. Large malls can also be sized at 30% of the central air conditioning total supply air volume. In industrial workshops where harmful substances are released, size the airflow to dilute the pollutant to a safe concentration.