Products
  • Condensing Exhaust-Air Heat-Recovery Fresh-Air Air-Conditioning Unit

    Condensing Exhaust-Air Heat-Recovery Fresh-Air Air-Conditioning Unit

  • Rooftop (Package) Unit

    Rooftop (Package) Unit

  • Modular Hygienic Air Han-dling Unit

    Modular Hygienic Air Han-dling Unit

  • Digital Smart Fresh Air Purification System

    Digital Smart Fresh Air Purification System

  • Long-Range Jet Air Handling Unit

    Long-Range Jet Air Handling Unit

  • Cabinet-Type Air Handling Unit

    Cabinet-Type Air Handling Unit

  • Fan Coil Unit

    Fan Coil Unit

  • Whole House Ventilating Dehumidifier (Uni-directional Airflow)

    Whole House Ventilating Dehumidifier (Uni-directional Airflow)

  • Whole House Ventilating Dehumidifier (Bi-directional Airflow)

    Whole House Ventilating Dehumidifier (Bi-directional Airflow)

  • Industrial Dehumidifier

    Industrial Dehumidifier

  • Ceiling-Mounted Dehumidifier

    Ceiling-Mounted Dehumidifier

  • Drying Dehumidifier

    Drying Dehumidifier

  • Low-Temperature Freeze-Type Dehumidifier

    Low-Temperature Freeze-Type Dehumidifier

  • Wine Cellar Dehumidifier

    Wine Cellar Dehumidifier

  • Cabinet-Type Constant Temperature & Humidity Unit

    Cabinet-Type Constant Temperature & Humidity Unit

  • Fresh-Air Dehumidification All-in-One Unit

    Fresh-Air Dehumidification All-in-One Unit

Air Treatment Equipment from ROTER

ROTER designs, manufactures and sells air treatment equipment from one factory in Wuxi, China. The range is built around a single objective: bring fresh outdoor air into a building without paying to heat and cool it again. Products are organised into five series, and every unit can be specified as a complete packaged system or built around a ROTER-made heat recovery core.

Five product series

Series What it covers Typical applications
Heat Recovery Ventilation Plate, rotary and heat pipe heat exchangers and heat recovery wheel units Ventilation energy recovery in residential, commercial and industrial systems
Fresh Air System Total heat recovery fresh air ventilators, DC inverter units, single flow haze removal units, wall-mounted and cabinet-type smart fresh air systems Houses, hotels, schools, offices, clinics and public buildings
Commercial Air Conditioning Unit  Combined air handling units, direct expansion units, condensing exhaust-air heat recovery fresh air conditioners and modular building-block AHUs Subways, airports, stadiums, malls, factories and cleanrooms
Air Conditioning Terminal  Long-range jet air handling units, cabinet-type air handling units and fan coil units Terminal equipment inside conditioned zones
Dehumidifier Wheel desiccant units, low dew point units, industrial, ceiling-mounted, drying, wine cellar and freeze-type dehumidifiers Warehouses, cold chain, museums, laboratories, wineries and industrial drying

Five series, one manufacturing base

Because ROTER integrates product design, production and sales rather than assembling bought-in parts, the heat exchanger core, the rotary desiccant rotor, the aluminium foil process, the fan, the control board and the cabinet are all produced under the same quality system. That is what makes the range consistent: a fresh air ventilator, an air handling unit and a dehumidifier from ROTER share the same approach to heat recovery efficiency, sealing and air leakage.

How to start a specification

  • Start from the air, not the equipment. Airflow, outdoor design conditions, the required indoor temperature and humidity band, and the noise limit at the occupied position determine which product family applies.
  • Then pick the recovery type. Plate cores for the lowest pressure drop and cleanest separation, rotary cores where the highest sensible and latent recovery is needed, heat pipe cores where condensate-free operation and long life matter, desiccant wheels where humidity must go below the comfort band.
  • Finally size the airflow. Fresh air volume is normally the larger of the per-person minimum (30–50 m³/h per person for general and high-grade offices and residences, 15–25 m³/h per person for shopping malls) or the air-change requirement (1–2 ACH for general rooms, 2–4 ACH for computer rooms).

Every product page in this section lists the technical parameters and the scenarios each unit is built for. If a project needs a configuration outside the standard range, send the requirement and the engineering team will propose a build to specification.

Inquiry Form

We will respond via email within 24 hours. Please keep your contact information available.